iManagement

Formic acid methods: what lies behind their differences?

Which statements correctly explain the differences between the summer treatment methods?

More than one answer is correct.

  1. With the Liebig dispenser, the acid must never be cold: it expands in the hive and too much escapes.
  2. With the FAM dispenser, the acid must also be at ambient temperature, for the same reason.
  3. The hotter it is, the higher the acid concentration should be so that the effect is sufficient.
  4. A continuing nectar flow or too high temperatures favour a 1st treatment without formic acid.
  5. Impregnated strips are the cheapest method, because no dispenser has to be bought.
  6. Liebig and Nassenheider allow evaporation to be checked; FAM, Apidea and strips do not.

Correct answers: 1, 4 and 6.
With the Liebig dispenser, the acid must never be cold: it expands in the hive and too much escapes.
A continuing nectar flow or too high temperatures favour a 1st treatment without formic acid.
Liebig and Nassenheider allow evaporation to be checked; FAM, Apidea and strips do not.

Why?

  1. True. With the Liebig dispenser, the acid must be at ambient temperature. If the temperature difference to the colony climate is too large, the contents expand and too much acid is pushed out of the bottle.
  2. False. With the FAM dispenser, working with cool acid is much more pleasant; the acid and filled dispensers can even be stored in the freezer, which reduces fumes.
  3. False. With the Liebig dispenser, above 25 °C only Formivar 60 % is generally used, to reduce the risk of queen loss and brood damage.
  4. True. A continuing nectar flow, too high temperatures or the wish to reduce the number of formic acid treatments favour brood interruption, complete brood removal or the trapping comb method for the 1st summer treatment.
  5. False. Impregnated strips are very easy to use, with no handling of open acid, but relatively expensive.
  6. True. With Liebig and Nassenheider, the amount evaporated can be checked and adjusted via the wick area or wick size; with FAM, Apidea and impregnated strips there is no check of the amount evaporated.

What to understand

Acid release is regulated by the wick area (Liebig), the wick size (Nassenheider), adjustable openings (FAM, Apidea) or the number of strips. Formic acid depends on temperature; methods without formic acid do not.

Key takeaway

Formic acid methods: Liebig never cold acid, FAM and Apidea cool acid more pleasant; in heat, lower concentration; evaporation check only with Liebig and Nassenheider; with a flow or heat, 1st treatment possible without formic acid.

Learn more

Back to overview